Sign In | Join Free | My chinacsw.com
China Meta Miner logo
Meta Miner
Global mining machine trade, North American mining machine hosting overall service
Active Member

3 Years

Home > Bitmain Antspace >

Customized Bitmain Antspace HK3 Crypto Mining Farm For S19 Hydro

Meta Miner
Contact Now

Customized Bitmain Antspace HK3 Crypto Mining Farm For S19 Hydro

Brand Name : ANTSPACE

Model Number : ANTSPACE HK3

MOQ : 1

Price : Negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 100

Delivery Time : Shipping Date: July 1-31, 2022

Packaging Details : Dimensions (L*W*H) (mm) 6058*2438*2896

Contact Now

customized ANTSPACE HK3 (with DWT-T/DWT-C) Mining farm for S19 hydro

Specification Details For ANTSPACE HK3

Product Overview

Version

ANTSPACE HK3

Dimensions (L*W*H) (mm)

6058*2438*2896

Miner Capacity

210 units -S19 Hyd. Series miner

Container Certification

China Classification Society Certification

Safety Certification

North America/Standards:NFPA 79:2021,UL 508A:2018 R8.21,
CSA C22.2 No. 14-18,ANSI/ISO 12100:2012
EU/Standards:EN ISO 12100,EN 60204-1

Operating Power(kW)

1047~1050

PUE(Power Usage Effectiveness)

1.022(Excluding cooling tower)/1.036(Including cooling tower)

Input Voltage and Frequency

415V±5% 60Hz(North America)
400V±5% 50Hz(EU,Middle East)

Detailed Characteristics

Shipping Weight(T)

8

Operating Weight (T)

12

Main Switch of Power Distribution Cabinets(A)

1200(North America)
1250(EU,Middle East)

Rated Current(A)

952

Standard Power(kW)

1049

Maximum Power(kW)

1050

Rated Current per Miner(A)

10

Inlet Cable

The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase:
L1 single core cable 600kcMil(300mm²)x4
L2 single core cable 600kcMil(300mm²)x4
L3 single core cable 600kcMil(300mm²)x4
N Single-core cable 600kcMil(300mm²)x4
PE single-core cable 500kcMil(240mm²)x2

Connection Interface(Cooling Tower)

DN125(GB/T 9119-2010 PN16 DN125)

Connection Interface(Plate Heat Exchage Interface)

DN100(GB/T 9119-2010 PN16 DN100)

Flow Rate(m³/h)

>85

Quantity of ANTSPACE powered by one 2500kVA Transformer

2

Specification Details For Dry-Wet Towers

One of the following two Dry-Wet Towers can be chosen based on the personalized demand.

Product Overview

Type

Dry-Wet Tower Traditional Type (DWT-T)

Dry-Wet Tower Container Type (DWT-C)

Dimensions(L*W*H)(mm)

5800*2240*4200

6058*2438*2896

Heat Dissipation Capacity(kW)

1000

1000

Outlet Temperature @ 28℃ Wet Bulb Temperature

35℃

35℃

Container Certification

None

China Classification Society Certification

Safety Certification

North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21,
CSA C22.2 No. 14-18, ANSI/ISO 12100:2012
EU Standards: EN ISO 12100, EN 60204-1

North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21,
CSA C22.2 No. 14-18, ANSI/ISO 12100:2012
EU Standards: EN ISO 12100, EN 60204-1

Operating Power(kW)

14~28

14~28

Motor Rated Voltage and Frequency

415V±5% 60Hz(North America)
400V±5% 50Hz(EU,Middle East)

415V±5% 60Hz(North America)
400V±5% 50Hz(EU,Middle East)

Detailed Characteristics

Shipping Weight(T)

5

6

Operating Weight(T)

9

10

Connection Interface(Container)

DN125(GB/T 9119-2010 PN16 DN125)

DN125(GB/T 9119-2010 PN16 DN125)

Water Resupply Pipe Interface

DN40(Internal thread)

DN40(Internal thread)

Drain Pipe Interface

DN65(Internal thread)

DN65(Internal thread)

Noise Level @25℃, 16m

70dBA

70dBA

Water Consumption(m³/h)

1~1.5

1~1.5

| Environmental Requirementss


Environmental Requirements

1

Cooling tower is required to be placed on flat ground, horizontal degree (±1 degree).

2

The ground surfaced is required to be hardened and stable, able to withstand at least 14-ton load.

3

A 10-ton crane is needed for unloading ANTSPACE and cooling tower.

4

Add-on items such as stairs, transformers, cables, bridge racks and cable distribution boxes are not included in the delivery of ANTSPACE. BITMAIN team can provide design suggestions if needed.

5

Client needs to confirm the opening directon of container and it needs to face air-intake. Door on left is current design by defult.

6

Keep at least 2 meters of air in-take space around the cooling tower.

7

Altitude: ≤3000m. If the altitude is higher than 1000-meter, transformer and switch should be derated, the total power of ANTSPACE must be decreased by 1% for each elevation increment of 100 meters.

8

Operating temperature: -25°C to 40°C. Operating humidity: 10%RH to 90%RH. When the initial coolant temperature is below 20 °C, the internal circulation should be turned on to heat up the coolant to above 20 °C before starting the mining machine.

9

When the ambient temperature is below 5 ℃, the cooling tower can be switched to cold-dry mode.

10

Choose pure water or suitable antifreeze as coolant based on local climate conditions.

11

The suitable ambient temperature for ANTSPACE does not represent the suitable ambient temperature for mining machine.

| Purchasing Guidelines


NOTES

1. The ANTSPACE HK3 is recommended to be used simultaneously with The ANTMINER S19 Pro+ Hyd. Please click here for more details on S19 Pro+ Hyd.

2. The pictures shown are for reference only; the final shipment version shall prevail.

Customized Bitmain Antspace HK3 Crypto Mining Farm For S19 Hydro


Product Tags:

HK3 Crypto meta miner tech

      

HK3 meta miner tech

      

S19 Hydro meta miner tech

      
Quality Customized Bitmain Antspace HK3 Crypto Mining Farm For S19 Hydro for sale

Customized Bitmain Antspace HK3 Crypto Mining Farm For S19 Hydro Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Meta Miner
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0